ZW-F type plasma active oxygen deodorization device, equipped with a unique collision absorption unit inside, intercepts and removes particulate matter in the odor; The multi-element gas collected by the odor collection system is subjected to a plasma active oxygen deodorization device. Under the action of a high-pressure plasma electric field, the ionized initial state oxygen ionizes and charges the odor ions for deodorization. The charged small ions (dust particles) are collected by the adsorption unit and flow into and deposit into the dust storage box of the gas treatment device. The harmful gases in the gas are sterilized by the ozone generated in the electric field, and the odor is removed. The harmful gases are removed, and the removal rate is tested to be over 90%. The clean air is discharged through the air outlet and meets the emission standards.
Product Details
based on experimental results and combined with data on the use of oxidation methods to treat odors abroad, the mechanism and main products of plasma purification equipment for treating various odor components have been basically determined. The main gas-phase pollutants contained in odorous pollutants include H2S, NH3, CH3SH, VOCs (organic compounds), etc.
There are two main ways for reactive oxygen species to remove the above-mentioned pollutants: one is to open the chemical bonds of certain harmful gas molecules under the instantaneous high-energy action of high-energy electrons, allowing them to directly decompose into elemental atoms or harmless molecules; The second is the oxidation and decomposition into harmless products under the action of a large number of high-energy electrons, ions, excited particles, oxygen radicals, and hydroxyl radicals (free genes have strong activity due to unpaired electrons).
The reaction mechanism is as follows:
H2S+O2, O2-, O2+→ SO3+H2O
NH3+O2, O2-, O2+→ NOx+H2O
VOCs+O2, O2-, O2+→ SO3+CO2+H2O
From the above reactions, it can be seen that the odor components will be transformed into small molecules such as NOx, SO3, H2O after equipment treatment. At a certain concentration, the conversion rate of various reactions is above 95%, and the odor concentration is low. Therefore, the concentration of the products is extremely low and can be accepted by the surrounding atmosphere.
■ Technical features:
1. The electric field of the reactive oxygen species purification unit adopts a cascade multi-element combination method, which can efficiently capture odor particles of different sizes, with high purification efficiency, averaging over 90%.
2. The high-frequency electrostatic power supply control system can automatically adjust the electric field strength and energy, which can maintain a high purification rate of gas purification equipment after long-term operation.
3. The high-frequency electrostatic power supply control system corresponds one-to-one with each purification unit, and the working status of each purification unit can be observed at any time for easy maintenance and repair.
4. The high-frequency electrostatic power supply control system has an automatic protection device for overcurrent and overvoltage to ensure the safe operation of the equipment.
5. Each cascade purification unit can be flexibly combined, and the number of units can be adaptively adjusted according to different purification rate requirements, thereby reducing equipment costs.
6. Each cascade purification unit adopts a split drawer design, which is easy to install and easy to clean.
7. The equipment is small in size, light in weight, and occupies a small area.
8. The use of corrosion-resistant materials and the long service life of the equipment are advantages.
Product advantages:
1. High purification efficiency and stable operation;
2. Compact structure, novelty, small size, light weight, modular structural design;
3. Noise level less than 75db (A), wind resistance less than 45 Pa;
4. Low operating costs and low power consumption; ≤500W
5. Easy cleaning and maintenance, long service life;
6. Safe, reliable, and reasonably priced.
Application areas:
1. Deodorization of sewage treatment sites, sewage pump rooms, garbage treatment sites, and garbage compression transfer stations
2. Air purification and disinfection of centralized air conditioning and ventilation systems in public places
3. Central air conditioning ventilation system air purification and disinfection
4. Industrial gas odor removal and purification
5. Oil fume purification, deodorization, etc
Precautions for pipeline design:
1. The variable diameter length of the air outlet of the active oxygen deodorization device must be greater than 750mm.
2. The distance between the odor collector and the air outlet should be greater than 1m.
3. The length of the air outlet duct should be greater than 10m.
4. The longer the air duct at the outlet of the active oxygen deodorization device, the better the deodorization effect.
Can be designed according to different gas flow rates of customers